Ion exchange calculations pdf

Each unit with a capacity of 120m3hour average breakthrough capacity of 2. This nebguide focuses on the ion exchange softening process which remains the most commonly used technique for managing hard water in residential settings. Ion exchange calculator 2 this calculator is under construction. Rohm and haas1 available on the internet as a pdffile. It does also include flow rate calculations, but for now, the size and capacity are solely related. Anion exchange chromatography, more specifically, uses a positively charged ion exchange resin with an affinity for molecules having net negative surface charges. Calculate the concentrations of cations and anions expressed as. Ion exchange in water deionization ion exchangers are also used in complete water deionization processes in this case both cationic and anionic exchangers are used regeneration of the exchangers is accomplished with strong acids or bases.

However it is worth mentioning it because it constitutes the largest application of ion exchange processes. Environmental ion exchange principles and design fundamental. Anion exchange chromatography is a form of ion exchange chromatography iex, which is used to separate molecules based on their net surface charge. It may also be described as the capacity for a soil to exchange cations for another. Ion exchange is a unit process in which ions of a given species are displaced. Chem 2115 experiment six separation of a mixture by ion.

Figure 1 shows a part of technical process bulletin of ionexchange resin amberjet 1200 na produced by. Ion exchange resins ion exchange resin is a crosslinked. Ion exchange systems are used for efficient removal of dissolved ions from water. Ion exchange resembles sorption in that, in both cases, a dissolved species is taken up by a solid. Pdf ion exchange design hand calculation zayn frivo. This document pdf may be used for research, teaching and private study. All natural waters contain some foreign substances, usually in small amounts. The method consists of complexing each of the components in the. Ion exchange plant design some basic principles you will not find here a complete plant design manual. For this purpose, the water is passed over a strongly acidic cation exchanger loaded with sodium ions. When you dissolve a salt into water, its cations and anions are free to wander as seen on figure 1. The cycle time for each cation anion pairing is determined by the water analysis, flow rate and number of streams. Their analysts see increased nuclear power demand and stringent environmental. Columns of cation exchange resin are used, and the solutions are maintained sufficiently.

A, figure 1, the exchanger is initially in a homoionic form e. An important use of ion exchange chromatography is in the routine analysis of amino acid mixtures. Schmidt, 2008 manufactured by introducing functional groups zeolites are crystalline aluminosilicates into a 3d crosslinked polymer matrix. For cation exchange resins, q0is in the range of 200 to 500 meq100mg of resin. Therefore, the same procedures used for the design of adsorption columns may be used for ion exchange columns. For example, retention of a metal cation on a cationexchange resin occurs by the following reaction.

Calculating cation exchange capacity and the percent base saturation the cation exchange capacity cec is a term used to describe the holding capacity of a particular soil for positivelycharged elements cations. This chapter provides a basic understanding of the ion exchange process, ion. Rohm and haas ion exchange ion exchange introduction 1 fd sep 2008 ion exchange for dummies an introduction water water is a liquid. For this reason, natural water does not exist as a chemically pure substance.

In a near neutral soil, calcium remains adsorbed on colloidal particle. Since dozens of factors can impact the productivity of the system, the cadix system design software program from dow offers precise design recommendations to optimize system performance. Regeneration occurs with a common salt solution of an elevated concentration. In typical binary batch process used for ion exchange studies e. The above calculations do not take into account flow rate, only capacity, but are the basis of the beginning of water softener design. Ion exchange is a process in which ions attached to a high molecular weight polymer are exchanged.

Ion exchange reaction ion exchange reaction applications of ion exchange. Ionexchange separation of metals by a singlepass method. Every ion that has been removed from the solution is replaced by an. Apr 15, 2008 abstract the article contains sections titled.

After reading this article you will learn about the cation and anion exchange in soil. A synthetic zeolite resin will be packed in shells with diameter of 5 ft. Drinking water containing some salinity is much better for health than ultrapure water. Schematic cation exchange resin bead rohm and haas, 2008 ion exchange on a zeolite source.

Ion exchange design procedures marmara universitesi. Charge ion exchange chromatography iex size size exclusion chromatography sec, also called gel. The breakthrough curves for an ion exchange column. In batch operation, a given amount m of ion exchanger is contacted with a given volume v of solution. Calculation on ion exchange capacity for an ion exchanger. Armenante njit ion exchangers in the treatment of inorganic and organic wastes in the vast majority of cases ion exchanger are used. Pdf ion exchange design hand calculation rupak deb. The water in the river, in a well or from your tap at home is not just h2o, it contains a little of. The characteristic difference between the two phenomena is that, ion exchange is a stoichiometric process while sorption is a non stoichiometric process. Steps to design an ion exchange resin system accurate system design is critical to getting the most from a water treatment system. Ion exchange separation of metals by a singlepass method abstract a singlepass method for the ion exchange separations of binary mixtures of metals is described, and experimental applications are presented.

Structure of ion exchange resins ion exchange equilibrium properties of ion exchange resins strong acid cation. Continuous ion exchangers consist of two columns in parallel. Ionic components of the mixture are differentially retained on the column by their differing affinities for ionic sites on the ionexchange resin. Design procedures the breakthrough curves for an ion exchange column and an adsorption column are similar. Ion exchange takes place in one column, while the resin in the second column is being regenerated, resulting in continuous operation. The resin has an exchange capacity of 320 kilograins of caco 3 per ft when regenerated at the 3rate of 15 ib of salt per ft. Since most ion exchange processes are reversible, the ion.

This calculator is based on theoretical calculations and explains how to use selectivity coefficients, separation factors and how to determine the maximum volume of water that can be treated with a resin before breakthrough happens. How to calculate ion exchange capacity theoritically. The ion exchange process is widely used for the removal of hardness as in softening, heavy metals as in waste treatment, radionuclides as from power plants and municipal water feeds removal of nitrates, arsenic, perchlorate, hexavalentchrome and others. I treated the surface of these glass particles with conc.

Ion exchange is widely used in the food and beverage industry, hydrometallurgy, metals finishing, chemical, petrochemical, pharmaceutical technology, sugar and sweetener production, ground and potablewater treatment, nuclear, softening, industrial water treatment, semiconductor, power, and many other industries. Ion exchange ix is the reversible interchange of ions between a solid and a liquid such as water. The mixture is agitated until equilibrium has been attained. In an ion exchange system, undesirable ions in the water supply are replaced with more acceptable ions. Ionexchange reaction applications of ion exchange britannica. Ion exchange reaction an overview sciencedirect topics. Rohm and haas ion exchange ion exchange introduction 3 fd sep 2008 ion exchange impurities in water water, as we have seen, contains small amounts of foreign substances. Ion exchange chromatography or ion chromatography, ic is a subset of liquid chromatog. Only a few general recommendations to ensure that an ion exchange system is designed economically and to achieve good performance, and a simple, but detailed example. The allowable effluent concentration, ca, is 5% co. With ionexchange softening, the calcium and magnesium ions are exchanged for sodium ions. The total salt content of water remains unchanged with this process.

An ion exchange process is to be used to soften water at the rate of 500 gpm. It is assumed that the breakthrough capacity remains the same. Ion exchangers exchange one ion for another, hold it temporarily, and then release it to a regenerant solution. Transfer1gramofcationexchangeresintoa150or250mlbeaker. Live calculations, functions and calculation procedures on. Ion exchange resins remove harmful contaminants from liquids, replacing them with beneficial, desired ions. The size of the water softener is dictated by the capacity.

Usage examples continuous ion exchangers are used when it is imperative that product be continually generated. Information on properties of ionexchange resins is supplied to users in two forms. It contains dissolved minerals, salts and organic compounds and also disperse and colloid. Claudia cobzaru, vassilis inglezakis, in progress in filtration and separation, 2015. For example, in a sodium zeolite softener, scaleforming calcium and magnesium ions are replaced with sodium ions. The calculator also shows some calculations that are needed for the sizing of an ion exchange installation. Ion exchange is used in water treatment, including water softening, industrial demineralization, condensate polishing, ultrapure water. I have used borosilicate glass particles which have coating of tio2 nanoparticles. Ion exchange is used for both analytical and preparative purposes in the laboratory, the analytical uses being the more common. Ion exchange resins have a limited number of exchange site available, and the total solid phase concentration q0is termed ion exchange capacity. Ion exchange as a physical process during ion exchange the ions being exchanged are reversibly removed from the wastewater and transferred to the ion exchanger this means that ion exchange is a physical separation process in which the ions exchanged are not chemically altered since the chemical characteristics of the ions. The capacity for exchange of an ion exchange resin is given in terms of meqml resin. The ion exchange water softening process can remove nearly all calcium and magnesium from source water. The process of ion exchange is one of the most utilized techniques in water and wastewater treatment as well as in separation processes as chemical synthesis, medical research, food processing, mining, agriculture, etc.